A laminar flow fume cupboard is a laboratory ventilation device similar to a Class II B2 biosafety cabinet. Its primary function is to shield the operator from harmful vapours and protect the sample from cross-contamination. This includes fumes and particulates generated during the scientific process.
It achieves this by creating an uninterrupted stream of HEPA filtered laminar flow air over the work surface. The air is then exhausted into the atmosphere using a roof-mounted ventilation stack. In addition to this, an external extract fan ensures a consistent face velocity to maintain the containment of harmful substances.
Our units feature 7" digital touch screens as standard with optional VAV control. TION's technology allows personnel to access critical airflow data reducing equipment downtime. We manufacture each unit using corrosion-proof welded polypropylene, extending the lifespan of our cabinets by up to 10 years.
Our products eliminate cross-contamination between different airstreams outside and inside the cabinet. It functions like a cleanroom on a smaller scale, which explains its ISO5 certification. These attributes make the product ideal for applications like trace metal analysis and contamination testing, where sample isolation is paramount. It also reduces corrosion and the filter replacement costs associated with something like a Class II biosafety cabinet.
Lighting is an essential aspect of the unit to ensure the safety of the operator and the specimen. The best option for lighting in a laminar flow fume cupboard is LED. It lasts longer and offers better clarity.
We often get asked about the practicality of manufacturing our fume cupboards from polypropylene, but the answer is surprisingly straightforward. The material is simple to maintain and clean. It's also mechanically rugged and features a high chemical resistance when compared with other metals and plastics.
A laminar flow fume cupboard produces an uninterrupted stream of air over the work surface. Laminar flow air (meaning smooth) reduces the chance of turbulence inside the cabinet, thereby preventing cross-contamination.
Our control panel software features a unique red-light alarm system. This system can be programmed to track air inflow and downflow, annual testing dates and filter replacements. Contact our team for a free product demonstration today.
Model | LAFFC1200 | LAFFC1500 | LAFFC1800 | LAFFC2000 | LAFFC2500 |
---|---|---|---|---|---|
External Size (W x D x H) | 1200 x 850x 2320 mm 47.3 x 33.4 x 91.3” | 1500 x 850 x 2320 mm 59.0 x 33.4 x 91.3” | 1800 x 850 x 2320 mm 70.9 x 33.4 x 91.3” | 2000 x 850 x 2320 mm 78.7 x 33.4 x 91.3” | 2500 x 850 x 2320 mm 98.4 x 33.4 x 91.3” |
Internal (workspace) Size (W x D x H) | 1000 x 600 x 800 mm 39.4 x 23.6 x 31.5” | 1300 x 600 x 800 mm 51.2 x 23.6 x 31.5” | 1600 x 600x 800 mm 63 x 23.6 x 31.5” | 1800 x 600 x 800 mm 70.8 x 23.6 x 31.5” | 2300 x 600 x 800 mm 90.5 x 23.6 x 31.5” |
Front Sash Max Opening | 720 mm / 28.3″ | 720 mm / 28.3″ | 720 mm / 28.3″ | 720 mm / 28.3″ | 720 mm / 28.3″ |
Production / Test Standard | EN-14175 / CE / ASHRAE 110-1995 | EN-14175 / CE / ASHRAE 110-1995 | EN-14175 / CE / ASHRAE 110-1995 | EN-14175 / CE / ASHRAE 110-1995 | EN-14175 / CE / ASHRAE 110-1995 |
Air Velocity | 0.5±0.1 m/s, 100±20 FPM | 0.5±0.1 m/s, 100±20 FPM | 0.5±0.1 m/s, 100±20 FPM | 0.5±0.1 m/s, 100±20 FPM | 0.5±0.1 m/s, 100±20 FPM |
Hood Material | Polypropylene | Polypropylene | Polypropylene | Polypropylene | Polypropylene |
Workstation Cleanliness | Class 100/ISO 5 | Class 100/ISO 5 | Class 100/ISO 5 | Class 100/ISO 5 | Class 100/ISO 5 |
Work Table Material | HPL/ Ceramic / Epoxy / PP / Stainless steel | HPL/ Ceramic / Epoxy / PP / Stainless steel | HPL/ Ceramic / Epoxy / PP / Stainless steel | HPL/ Ceramic / Epoxy / PP / Stainless steel | HPL/ Ceramic / Epoxy / PP / Stainless steel |
Control System | VAV System with 9” colour touch screen | VAV System with 9” colour touch screen | VAV System with 9” colour touch screen | VAV System with 9” colour touch screen | VAV System with 9” colour touch screen |
Optional | Water tap/ gas tap / vacuum tap/ pp sink | Water tap/ gas tap / vacuum tap/ pp sink | Water tap/ gas tap / vacuum tap/ pp sink | Water tap/ gas tap / vacuum tap/ pp sink | Water tap/ gas tap / vacuum tap/ pp sink |
Power Supply | 110/220V, 50/60 Hz, Includes a single phase power supply. A three-phase power supply can be specially ordered. | 110/220V, 50/60 Hz, Includes a single phase power supply. A three-phase power supply can be specially ordered. | 110/220V, 50/60 Hz, Includes a single phase power supply. A three-phase power supply can be specially ordered. | 110/220V, 50/60 Hz, Includes a single phase power supply. A three-phase power supply can be specially ordered. | 110/220V, 50/60 Hz, Includes a single phase power supply. A three-phase power supply can be specially ordered. |
Illumination | 800 LUX LED lights | 800 LUX LED lights | 800 LUX LED lights | 800 LUX LED lights | 800 LUX LED lights |
The difference between a laminar flow fume cupboard and a Class II B2 biosafety cabinet lies in the filtration of the extract. Laminar flow fume cupboards feature no extract filtration and should not be used for dangerous biological samples.